room science

How rooms, furniture and indoor air behave in the UAE climate, read from the research and the rules

New UAE efficiency rules for air conditioners: what changed in November 2025

Filed in Heat and cooling

Published 29 November 2026 by the editors of Room Science, 4 min read

Stacked cardboard boxes of new air conditioners in a store aisle under bright lights
Boxed split air conditioners in a store. The UAE labelling standard of 2014 required the energy label on the unit and on its carton.

The UAE replaced its rules for the energy efficiency of air conditioners in November 2025. Cabinet Resolution No. 157 of 2025, issued on 4 November 2025 and in force from 15 November 2025, made a new set of technical regulations for low and large capacity air conditioners mandatory across the country, and gave the parties it covers 365 days from that date to bring themselves into line. The transition window closed in mid-November 2026, so units on sale this winter fall under the new regulations.

What the resolution does

The resolution is short, and its four articles do three things. Article 1 makes the energy efficiency technical regulations listed in its schedule mandatory in the UAE. Article 2 gives all concerned authorities existing when the resolution took effect 365 days to regularise their status. Article 3 repeals Cabinet Resolution No. 3 of 2020, which had made earlier standard specifications for the electricity sector mandatory. The resolution was published in Official Gazette No. 811 on 14 November 2025 and took effect the following day.

The detailed requirements, including the star bands, sit in the technical regulations named in the schedule rather than in the resolution itself. For a shopper, the figure on the label is what matters.

What the star label measures

Under the 2014 standard, the UAE label rated a unit on a five-star scale by its energy efficiency ratio (EER): cooling output in British thermal units per hour for each watt of electricity drawn, measured under standard test conditions. A higher EER means more cooling for the same power. The International Energy Agency's policy database records the bands of the previous standard, UAE.S 5010-1:2014, which applied to non-ducted split and window units from 1 November 2015:

Split units under the 2014 standard EER band
1 star 6.80 to 7.10
2 stars 7.11 to 7.70
3 stars 7.71 to 8.30
4 stars 8.31 to 9.00
5 stars 9.01 and above

The 2014 bands describe the label carried by air conditioners sold in the UAE from late 2015 until the new regulations. The 2025 regulations replaced that standard, so a star count on a new box is not directly comparable with the star count on a unit bought ten years ago. The EER figure itself, printed on the label or in the specification sheet, is the number to compare.

Three white wall-mounted indoor air conditioning units on a grey showroom wall
Indoor units on a showroom wall. Units that look alike can differ in efficiency, and the efficiency figure on the label is the number to compare.

What a better unit saves: a worked example

The difference between star bands is easiest to see in kilowatt-hours. Take a 12,000 Btu/h split unit at the two ends of the 2014 bands, running 10 hours a day for about six months, priced at DEWA's residential tariff for November 2026.

Unit with a rated cooling output of 12,000 Btu/h EER 7.0 (1 star in 2014) EER 9.1 (5 stars in 2014)
Power drawn at rated conditions about 1.71 kW about 1.32 kW
Electricity over 1,800 hours (10 hours a day for about six months) about 3,090 kWh about 2,370 kWh
Difference about 710 kWh
Cost of the difference at AED 0.28 plus a 0.06 fuel surcharge per kWh, plus 5% VAT about AED 254 a year

DEWA charges 23 fils per kWh for the first 2,000 kWh of residential consumption in a month and 28 fils from 2,001 to 4,000 kWh, plus a fuel surcharge that DEWA set at 6 fils per kWh for November 2026, with 5% VAT on top. A home that runs several units through summer usually spends its peak months in the higher slabs, which is why the example uses the 28-fil rate. The note on DEWA's slab tariff works through a whole summer bill.

Real savings depend on use. Rated EER is measured at fixed test conditions, while a unit in a UAE summer runs at higher outdoor temperatures, part load and with whatever dust its coil has collected, as the note on filters and coils explains.

What DEWA advises about old units

DEWA's own conservation guidance is direct on replacement. DEWA describes ten years as the optimal lifetime of an air conditioner and suggests that owners of older units replace them with new energy-efficient units rated 4 or 5 stars, which DEWA says can save up to 25% of cooling consumption. The same DEWA page recommends setting thermostats at 24 °C or higher, since each degree of increase can save up to 5% of air conditioning consumption. Whole buildings are rated as well, as the note on green building ratings and awards in the UAE explains.

An old window air conditioner fitted into the wall of a villa bedroom, its front grille yellowed with age
An old window unit in a villa wall. DEWA describes ten years as the optimal lifetime of an air conditioner.

Buying checklist

A buyer comparing models this winter can check five things.

  1. Compare the EER, or the efficiency figure printed on the label, rather than the star count alone.
  2. Match the cooling capacity to the size of the room, using the capacity printed on the label or specification sheet.
  3. Ask whether the unit carries the current UAE label on both the unit and its carton.
  4. Plan where the outdoor unit goes: shade and airflow around it help it reject heat.
  5. Budget for upkeep, since a five-star unit with a clogged coil performs like a cheaper one.

A new unit is not the only lever. Ceiling fans, covered in the note on raising the thermostat with a fan, and shading, covered in the notes on curtains and blinds and window film, cut the cooling a home needs before any unit runs.

Sources

  1. UAE Legislation portal (2025). Cabinet Resolution No. (157) of 2025 regarding the technical regulations for energy consumption efficiency requirements for low and large capacity air conditioners
  2. International Energy Agency, policies database (2020). UAE.S 5010-1:2014 household air-conditioners
  3. Dubai Electricity and Water Authority (DEWA) (2026). Cooling: conservation tips
  4. Dubai Electricity and Water Authority (DEWA) (2026). Slab tariff

Tags: air conditioningenergy labelregulationefficiencyDEWA